Skip to content
Home Assistant TestFlight
Fronius

Fronius Wattpilot

Sensors · Security

Partly worksLocal

1 report: 1 says it partly works.

Reported with 1 integration: go-e APIv2 Connect.

What people report

IntegrationIn Home AssistantIn Apple HomeWhat they saidSource
go-e APIv2 ConnectPartly works LocalWebSocket-only; LAN setup fails, fallback fix PR closed unmerged
Saved copy
Problem Fronius Wattpilot chargers cannot be added via the LAN flow. The setup always fails with "Host/IP is wrong - could not reach system", even when the WebSocket wallbox password is provided. Root cause: the Fronius firmware does not offer the local HTTP APIv2 at all, `GET http:// /api/status` is answered by the device's nginx with `502 Bad Gateway`, and `GET /` responds with `The WebSocket handshake Upgrade field is missing` (the device is WebSocket-only). Since `_test_host()` (config flow) and `read_versions()` (entry setup) exclusively use `_read_filtered_data()` (HTTP), a Wattpilot …

Excerpt saved from GitHub on 2026-10-23.

PR #158 · 2026-09

Each row is one report from a GitHub thread, an integration’s docs, or r/homeassistant. Check the date and the linked source before you buy.

In ReReHome

Once Home Assistant’s HomeKit Bridge shares it, this device reaches Apple Home as a HomeKit accessory behind your Home Assistant bridge, so ReReHome shows and controls it like any other.

Identifiers

BrandFronius
ModelWattpilot
CategorySensors