IntegrationIn Home AssistantIn Apple HomeWhat they saidSource
Ness AlarmWorks LocalArm/disarm commands lost with 5 s polling; default restored to 60 s
Saved copy
The problem ### The problem Since the Ness Alarm integration was moved to the UI, `DEFAULT_SCAN_INTERVAL` in `const.py` is hard-coded to 5 seconds, and there is no longer any option to change it (the old YAML `scan_interval` is gone). Each cycle sends four status requests (S00, S20, S14, S18). The D8x/D16x panel answers roughly one request every 1.6 seconds, so requests pile up faster than they are answered. After a few minutes, arm and disarm commands are written to the interface but never acted on by the panel. Reloading the integration clears the backlog temporarily, then the problem …