What people report

IntegrationIn Home AssistantIn Apple HomeWhat they saidSource
SolaX Inverter ModbusWorks Localpv_power_total regression on old firmware; fixed after SolaX firmware update
Saved copy
Bug Description After updating to `2026.05.2`, `sensor.pv_power_total` returns a constant 1W on a SolaX X1-VAST inverter. The individual string sensors (`pv_power_1`, `pv_power_2`) continue to work correctly. ## Root Cause Commit `fc0a7ee` changed `pv_power_total` from a calculated sum of string sensors to reading Modbus register `0x32` directly, with support limited to `HYBRID | GEN6` (with a note that *"GEN5 testing needed"*). On the X1-VAST, register `0x32` returns a constant 1W, it either does not exist or maps to a different value on this hardware. Prior to this commit, `pv_power_total` …