homebridge-ups · v1.3.11

VerifiedLocalHomebridge 2.0

Adds UPS devices from Network UPS Tools with battery and power status plus alarm control.

What it says it supports

Brands

  • Network UPS Tools

Devices it names

  • NUT-connected UPS devices

Shows up in Apple Home as from its README

What people report

Works with UPS units via NUT; available values depend on what each UPS reports, and newer APC units report little.

  • Partly works2

The plugin’s own supported-device list

DeviceStatusWhat they saidSource
APC SMT2200 UPSPartly worksWorks but reports no consumption; newer APC UPS expose few variables
Saved copy
Here's the dump of `ups info`: It doen't look like your UPS reports consumption, nor anything that can be used to compute this. My UPS reports `ups.realpower.nominal` (nominal power in W) and `ups.load` (percentage of nominal power provided), which Homebridge UPS uses to compute consumption. I've also seen UPSs that report `output.current` (in A) and `output.voltage` (in V), which Homebridge UPS can use alternatively. [9/7/2024, 5:16:01 PM] [Mech Room Rack UPS] Mech Room Rack UPS Battery: Voltage: set to 30V [max] Hm, you have a (nominal) 48V battery, which actually runs at 53.1V. I need to …

Excerpt saved from GitHub on 2026-10-22.

Issue #24 · 2024-09
Eaton 3S 850 UPSPartly worksVoltage and consumption showed null; fixed parsing in beta, battery voltage stays 0
Saved copy
Eaton 3s 850: set Voltage to nullV Homebridge UPS reads the mains voltage from `input.voltage`, which your UPS doesn't report. I suppose I could use `output.voltage` instead, or simply not expose _Voltage_. Eaton 3S 850 Battery: set Voltage from nullV to nullV Homebridge UPS reads the battery voltage from `battery.voltage`, which your UPS doesn't report. I'm afraid the only solution here, is not to expose the battery _Voltage_. set Current Consumption to nullW Homebridge UPS computes the consumption from `ups.load` (which indicates the load as percentage) and `ups.realpower.nominal`, which …

Excerpt saved from GitHub on 2026-10-22.

Issue #5 · 2022-10

Gathered from the plugin’s GitHub issues, pull requests, discussions, wiki and docs, and from r/homebridge. These are individual reports, so check the linked thread and the date before you buy.

How it connects

Local

NUT upsd socket on port 3493

You’ll need

  • Network UPS Tools (upsd)

Compatibility

Verified by HomebridgeYes
Homebridge versions^2.4.0
Homebridge 2.0Yes
Node.js^24||^22
Settings in Homebridge UIYes
MatterNo
Platform nameUPS
LicenseApache-2.0

Community signals

Downloads a week101
Downloads a month312
GitHub stars29
Open issues0
Closed issues29
Last code push2026-08-29
Latest version1.3.11 (2026-08-29)
First published2022-09-18
Releases54